Contact Sales Fox Thermal
Fill out the form below to contact a Fox Thermal Representative.
Need to talk to someone immediately, give us a call, 831-384-4300.
Are you sure you want to log out?

The Model FT2A has a large selection of communication protocol options available intrinsically (without any other equipment). Options include: BACnet MS/TP, RS485 Modbus RTU, Profibus-DP, DeviceNet, or Ethernet Modbus TCP.
Key Features:
Industrial Applications:
The free FT2A View™ software from Fox Thermal is a great way to connect your PC or laptop to the FT2A in order to access the meter settings in a quick and easy way. This software offers:
Note: For FT2A View™ software to function properly, please be sure to have a working version of Microsoft® Office installed on the PC before installing FT2A View™.
USB Driver and the Fox Thermal FT2A View™ Software
A USB driver is needed for FT2A View™ to run. If the USB drive does not install automatically, you will need to download it by following this link. Instructions are included on how to install it correctly.
Flow meter accuracy is often dependent on achieving a uniform flow profile near the center of the pipe. Distortion and swirl are disturbances in flow that can be remedied either by extending the length of space between the cause of the disturbance and the sensing element (increasing straight pipe runs) or by adding a flow conditioner to correct the disturbance. Flow conditioners installed upstream of flow meters reduce the need for long, straight pipe runs. Common Features for Fox Thermal FC20 Flow Conditioner:
More Info
| Technical Specifications | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Fox Thermal Model FT2A Thermal Mass Flow Meter & Temperature Transmitter | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Performance Specs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type | Insertion | Inline | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Accuracy: | ± 1% of reading ± 0.2% of full scale. 15 diameters of straight, unobstructed pipe upstream and 10 downstream. |
± 1% of reading ± 0.2% of full scale. 8 diameters of straight, unobstructed pipe upstream and 4 downstream. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Repeatability: | ± 0.2% of full scale | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Response Time: | 0.9 seconds (one time constant) | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature Accuracy: | ± 1.8°F (± 1.0°C) -40 to 250°F (-40 to 121°C); ± 3.6°F (± 2.0°C), 250 to 650°F (121 to 343°C); 60 SFPM minimum. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Calibration: | Factory Calibration to NIST-traceable standards | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Operating Specs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type | Insertion | Inline | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Units (field selectable): | SCFM, SCFH, NMPS, NM3/M, NM3/H, NM3/D, NLPS, NLPM, NLPH, MCFD, MSCFD, SCFD, MMSCFD, MMSCFM, SMPS, SM3/H, LB/S, LB/M, LB/H, LB/D, KG/S, KG/M, KG/H, SLPM, SFPM, MT/H, SM3/M | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Rates: | 15 to 60,000 SFPM (0.07 to 280 NMPS) - Air at 70°F (20°C) & 1 ATM | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Turndown: | up to 1000:1; 100:1 typical | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Flow Ranges: |
|
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Note: Standard conditions of air at 70°F and one atmosphere. Consult factory for other gases, pipe sizes, and flow ranges other than those listed. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Gas Pressure (max): | 500 psig (34.5 barg) |
316 SS inline w/NPT ends: 500 psig (34.5 barg) 316 SS inline w/150lb flanges: 230 psig (16 barg) CS inline w/NPT ends: 500 psig (34.5 barg) CS inline w/150lb flanges: 285 psig (20 barg) |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Check with factory for higher pressure options. Note: Pressure ratings stated for temperature of 100°F (38°C). |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Relative Humidity: | 90% RH maximum; non-condensing | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature by Sensor Type: | ST Sensor: -40 to 250°F (-40 to 121°C) HT Sensor: -40 to 650°F (-40 to 343°C) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Temperature by Enclosure: | DC Power: -40 to 158°F (-40 to 70°C) AC Power: -4 to 158°F (-20 to 70°C) |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Inputs Power (Power Consumption): |
Note: Fluctuations of AC and DC power supply are not to exceed ±10% of rating.
Class I Equipment (Electrical Grounding Required for Safety). Installation (Over-voltage) Category II for transient over-voltages. |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Outputs: |
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Port: | Mini USB communication port is standard. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Software: | The free PC-based software tool - FT2A View™ - provides complete configuration, remote process monitoring, and data logging functions. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Optional serial communication: | Modbus RTU (RS485), BACnet MS/TP (RS485), Profibus-DP, DeviceNet or Ethernet Modbus TCP. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| 4-20mA Loop Verification: | Simulation mode used to align 4-20mA output with the input to customer’s PLC/DCS. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Physical Specs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Type | Insertion | Inline | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Sensor Material: | 316 stainless steel standard. Hastelloy C276 optional. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Enclosure: | FM (U.S.) & FMc (Canadian) approved for Class I, II, III, Division 2, Groups A, B, C, D, E, F, G, T4A hazardous locations. NEMA 4X and CE approved. Options: Remote NEMA 4X electronics enclosure with explosion-proof sensor j-box. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Cabling to remote enclosure: | 5-conductor, 18 AWG, twisted, shielded, 100 feet maximum. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Retractor Assemblies: | Packing gland assembly: 125 psig (8.6 barg ) max. High pressure (crank) retractor: NPT 600 psig (41.4 barg), ANSI 150 flange & ANSI 300 flange, no valve supplied. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Installation: | Fox Thermal-supplied compression fitting connects to customer-supplied ¾" female coupling welded to pipe. | Compression fitting included with flow body | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
CE: Approved
Note: the EU Pressure Equipment Directive (PED) requires that the minimum abient and fluid temperature rating for carbon steel flow bodies not be below -29°C.
FM (U.S.) and FMc (Canada): Approved
Talk with our application specialist or a rep near you for sizing and materials requirements
| Model FT2A View™ Information to View and/or Download | |
|---|---|
| FT2A View™ Software v. 2.2 | |
| FT2A View™ Datasheet | |
| FT2A View™ Manual | |
| VCP Driver (for FT2A View™ Software) | |
Note regarding VCP Driver: If the PC is connected to the Internet and running Windows® 7, 8, or 10, the PC will try to automatically load the VCP driver. If the driver does not load automatically, we have supplied a link above.
Winner of 2014 Processing's Breakthrough Products Award!
Processing Magazine has awarded Fox Thermal’s Model FT2A Thermal Mass Flowmeter & Temperature Transmitter the Breakthrough Products of the Year award for 2014. These awards recognize products, technologies and services that made significant contributions in the process industries within the last year and are expected to impact the industry for years to come.
Read the article describing the FT2A’s point of use in natural gas applications.
Winner of Flow Control’s 2014 Innovation Award!
The votes have been tallied! The Fox Thermal Model FT2A Thermal Mass Flowmeter and Temperature Transmitter has won the Flow Control 2014 Innovation Awards. The great variety of on-board communication options - including the addition of BACnet MS/TP - available on the FT2A has led to this win! Fox Thermal is very pleased and would like to thank all who have voted for this outstanding product.
Read the Digital Issue of Flow Control's Announcement...
The Fox Thermal Model FT2A, winner of both the 2014 Flow Control Innovation Award and the Processing Breakthrough Product Award, is the most widely versatile Thermal Gas Mass Flow Meter on the market today.
The Model FT2A has a large selection of communication protocol options available intrinsically (without any other equipment). Options include: BACnet MS/TP, RS485 Modbus RTU, Profibus-DP, DeviceNet, or Ethernet Modbus TCP.
The Model FT2A measures gas flow rate in standard units (SCFM, NM³/hr, LBS/HR, KG/HR & many more) without the need for temperature and pressure compensation. See the Features/Benefits section below to explore all that the FT2A can offer your application.
For complete specs please see the Fox Thermal Model FT2A Flow Meter Datasheet.
Copyright © 2025
Fox Thermal | 399 Reservation Rd. | Marina, CA 93933 | (831) 384-4300 | www.foxthermal.com
This site uses cookies. We use cookies mainly to improve and analyze your experience on our websites and for marketing purposes. Because we respect your right to privacy, you can choose not to allow some types of cookies. Click on the different category headings to find out more and change your default settings. Blocking some types of cookies may negatively impact your experience on the site and limit the services we are able to provide.
Necessary cookies enable core functionality such as security, network management, and accessibility. You may disable these by changing your browser settings, but this may affect how the website functions.
Analytics cookies help us improve our website by collecting and reporting information on its usage.
We use cookies to make our ads more engaging and valuable to site visitors. Some common applications of cookies are to select advertising based on what’s relevant to a user; to improve reporting on ad campaign performance; and to avoid showing ads the user has already seen.
We use a set of cookies that are optional for the website to function. They are usually only set in response to information provided to the website to personalize and optimize your experience as well as remember your chat history.
Subscribe to Fox eNewsletter
Stay up to date with the latest news, product updates, and industry insights from Fox Thermal.
Sign up below to receive our newsletter directly in your inbox.
We respect your privacy. Unsubscribe at any time.